NedaMed
Telephone : +98 (311) 6532771
Fax & Voice Mail : +98 (936) 2619966
info@NedaMed.com
Technology of Innovators

Since 1998, NedaMed Co. has been a leader in supplying superior instruments and assessments for basic scientific research and practice. We are proud of our tradition of Researching and supplying superb products…and remain committed to our customers' needs through knowledgeable and prompt customer service.

 

Intrathecal Baclofen (ITB) Pump Therapy

The Medtronic SynchroMed® EL Infusion System is an implantable, programmable drug delivery system used to treat pain, spasticity, and cancer.
This system has been commercially available since 1988, and consists of the following components:

  • An implantable, programmable pump

  • An intrathecal catheter

  • An external programmer

The SynchroMed EL Infusion System is indicated for:
• Chronic intrathecal or epidural infusion of sterile, preservative-free morphine sulfate for chronic, intractable pain of malignant and/or benign origin;
• Chronic infusion of baclofen for severe spasticity of spinal or cerebral origin;
• Chronic intravascular infusion of chemotherapy for the treatment of cancer:
o Floxuridine (FUDR)
o Doxorubicin
o Methotrexate
o Cisplatin
• Chronic intravenous infusion of clindamycin for the treatment of osteomyelitis.


The CODMAN® 3000

The CODMAN® 3000 Infusion Pump is a cost-effective therapy for those patients that fail conventional medical treatment. This elegantly simple device features an inexhaustible power supply, and does not require frequent replacements associated with battery powered pumps. The slow, continuous drug delivery of the constant flow pump into the intraspinal space eliminates the peaks and valleys often experienced with traditional drug therapy.

The Codman 3000 implantable pump is divided into inner and outer chambers by accordion-like bellows. The inner chamber that contains the drug to be infused. The outer chamber contains propellant permanently sealed inside.

The patient's own body temperature warms the propellant, which exerts a constant pressure on the bellows. This causes the drug to flow out of the inner chamber through a filter and flow restrictor then slowly out of the catheter.


Syringe Pump (SK-500III)

Applicable syringes: Meeting all national standard syringes of 10ml, 20ml and 50ml
Feasible injection rate range:
1ml: 0.1~10ml/h
5ml: 0.1~50ml/h
10ml: 0.1~100ml/h|
Injection increment: 0.1ml/h
Feasible preset injection quantity range: 0.1~999.9ml
Fast injection speed:
1ml injector :10ml/h
5ml injector :50ml/h
10ml injector: 100ml/h
Accumulated injection quantity: 0.1~999.9ml
Injection precision: +/-3%


Infusion Pump (SK-600I)

Infusion pump are economical products of intellectualization, collectivization and hi-tech which can be used in all clinics or wards, thus promoting the previously single pump intravenous infusion control to mass control. The patients' infusion situation and alarm information (eg. OVER, pipe occlusion) can all be seen at the nurse's station. This greatly improves the medical nursing quality, reduces the nurse's workload, and ensures the patient's nursing safety.
It is also used in hospitals where patients need intravenous infusion at steady speed or continuous and precise infusion.
 


Product Feature: >
1. Unique door-free structure design. It makes this medical equipment easier and more convenient to operate. Pull up the handle and put in the injection tube from the middle. Then pull down the handle. Whether the tube is in its place or not will be automatically indicated. Press the startup button to start the infusion.

2. Unique infusion supervision function. Key in a bed number and the infusion supervision management system at the nurse station will simultaneously display the infusion progress or alarm information of the patient of this bed number. This realizes the dream of giving the patient an accurate infusion while supervising his infusion.

3. The unique door-free infusion pump completely prevents infusion tube from deviation, thus enabling a safe infusion process. Air detector and pressure sensor can precisely detect tube air bubbles and blocking situation followed with an immediate alarm signal.

4. Application of double CPU, making the infusion process safer and more reliable.  running
Product Specification: >
1. Power supply: 50/60 Hz AC 100V~240V,
2. Operation condition:
Operation temperature: 5~45C,
Air pressure 70~106KPa,
Relative humidity 30%~90%
3. Applicable and adjustable for all infusion sets.
4. Infusion rate: 1ml/h~600ml/h
5. Alarm function: OVER, OCCL. Low battery, installation error, AIR, EMPTY, Machine malfunction.
6. KVO rate: 1ml/h
7. Electrical safety: In accord with the stipulation of GB9706.1-199.5, EN60601-1 and UL60601-1.
8. Battery: Rechargeable lithium battery, 7.4V, 1400mA.
 


Infusion Pump (SK-600IB)

Infusion pump are economical products of intellectualization, collectivization and hi-tech which can be used in all clinics or wards, thus promoting the previously single pump intravenous infusion control to mass control. The patients' infusion situation and alarm information (eg. OVER, pipe occlusion) can all be seen at the nurse's station. This greatly improves the medical nursing quality, reduces the nurse's workload, and ensures the patient's nursing safety.
It is also used in hospitals where patients need intravenous infusion at steady speed or continuous and precise infusion.

 

Product Feature: >

Bolus 600ml/h
Flow rate range 1-2000ml/h
Volume limit 1-9999 ml
Accuracy +/-5%
Display or information
Flow rate, volume limit, accumulated volume, power indicator light, bed No., air, occlusion, empty.
Alarm function
Infusion completion, occlusion, air bubble, low battery, control abnormal,
No AC power supply, installation error.
Max. Size of outer shell 120*140*190 mm (length*width*height)
Max. Weight <2.5 kg
Classification Type BF.
Outer shell material ABS plastic
Operating condition
Environment temperature +5- +40, atmosphere pressure 86-106kPa, related humidity 20%-90%
Storage and transport condition
Environment temperature -15- +50, atmosphere pressure 86-106kPa, relative humidity 20%-90%.
Applicable infusion pipe
All standard infusion pipe.
Work mode
Continuous work mode
Applicable standard
Comply with standard of EN ISO 14971: 2000, IEC 60601-1: 1995, EN IEC 60601-1-2: 2001, IEC 60601-2-24, EN ISO 14155-1: 2003, EN 980: 2003, EN 1041: 1998, MDD 93/42 EEC

News

September 3, 2008
Léger Survey reports 84 per cent of Ontario physicians feel patients may be addicted to prescription painkillers
September 3, 2008
Prescription painkiller dependence is a serious problem in Ontario, according to the results of a new survey conducted by Léger Marketing polling 211 Ontario General Practitioners. The survey reports that the majority of Ontario physicians (84%) feel that their patients may be addicted to commonly-prescribed painkillers.

More...

September 3, 2008
College freshmen: Pain killers and stimulants less risky than cocaine; more risky than marijuana
September 3, 2008
First year college students believe that occasional nonmedical use of prescription pain killers and stimulants is less risky than cocaine, but more risky than marijuana or consuming five or more alcoholic beverages every weekend, according to a new study published in the September issue of Prevention Science.

More...